How Big Is a Cell?
Measure the field of view with a ruler, then use it as a scale to calculate the real size of a cell in micrometres.
What students learn
Students calibrate the microscope by measuring the field of view with a transparent ruler, calculate the field at higher magnifications, and use it as a scale to convert a cell count into a real cell size in micrometres.
The science behind this experiment
- One millimetre equals 1000 micrometres. Cell sizes are quoted in micrometres because most cells are far below 1 mm.
- Field of view diameter is inversely proportional to magnification: FOV(high) = FOV(low) x magnification(low) / magnification(high).
- A known field of view acts as a ruler inside the image, so any object can be measured by comparing it with the field.
- Counting several cells across a field and dividing gives a better estimate than measuring one cell, because random errors partly cancel.
- Repeating the count in three fields and averaging reduces the effect of unusually large or small cells.
Key relation: FOV(high) = FOV(low) x mag(low) / mag(high) | Cell size = FOV / number of cells across | 1 mm = 1000 micrometres
Equipment used
- Digital microscope (10x eyepiece; 4x, 10x, 40x objectives)
- Transparent ruler with millimetre divisions
- Prepared or student made onion epidermis slide
- Prepared slide set, animal tissue
- Tablet or computer for image capture
- Calculator
Questions for students
- Why does counting several cells across the field give a better estimate than measuring a single cell?
- Your three fields give 280, 310 and 450 micrometres. What would you do with the third value, and how would you justify that decision?
- Design a method to measure a cell that is much smaller than the divisions of any ruler you own, using only this microscope and objects of known size.
What to expect
Field of view is about 4.5 mm at 40x total magnification, about 1.8 mm at 100x, and about 0.45 mm at 400x. Counting about 6 onion cells across the 1.8 mm field gives 0.30 mm, that is about 300 micrometres per cell, which matches the accepted range of 200 to 400 micrometres. Animal cells measured the same way give about 50 to 70 micrometres. The field of view acts as a built in ruler. Measured at low power and scaled to higher magnifications, it converts a simple cell count into a real size. Onion epidermis cells measure about 200 to 400 micrometres and animal cells about 50 to 70 micrometres.
Run this experiment in your classroom
This experiment is part of ATP Volta — a self-contained mobile science lab that turns an ordinary classroom into a working STEM laboratory, with over 200 experiments in physics, chemistry, biology, robotics and engineering. Gali, the AI tutor built into ATP Connect, guides students through each step and answers their questions at the bench.
See the ATP Volta mobile science labTalk to our team