The Heart as a Double Pump
Open the model heart to trace both circuits, then build a squeeze-bottle pump with clip valves and measure its output in litres per minute.
What students learn
Students open the two-part heart of the mini torso to identify the four chambers, the septum, the valves and the great vessels, and trace the pulmonary and systemic circuits. They build a one-chamber pump from a squeeze bottle with two Mohr clips as valves, measure the volume per squeeze and the number of squeezes per minute, and calculate output the way cardiac output is calculated: stroke volume × heart rate, about 70 mL × 70 beats per minute ≈ 4.9 L/min at rest.
The science behind this experiment
- The heart is two pumps side by side: the right side receives oxygen-poor blood from the body through the venae cavae and sends it to the lungs through the pulmonary artery (pulmonary circuit); the left side receives oxygen-rich blood from the lungs through the pulmonary veins and sends it to the body through the aorta (systemic circuit).
- Each side has an atrium that collects blood and a ventricle that pumps it; four valves (two between atria and ventricles, two at the ventricle exits) open and close with pressure differences so blood flows one way, and the 'lub-dub' sounds are the valves closing.
- The left ventricle wall is 8 to 12 mm thick against 3 to 5 mm for the right, because it pumps the same volume per beat against the body's pressure of about 120 mmHg while the right pumps against the lungs' 25 mmHg; both ventricles must move the same volume on average or blood would pile up in one circuit.
- Cardiac output = stroke volume × heart rate: about 70 mL × 70 beats per minute = 4.9 L/min at rest, close to the total blood volume of about 5 L, so all the blood passes through the heart about once a minute; in hard exercise output rises to about 20 L/min.
- The pump model copies a ventricle: the bottle is the chamber, squeezing is systole, elastic recoil is diastole, and the two clips are the inlet and outlet valves; the real heart's valves need no hands because they are pushed open and shut by blood pressure.
- The heart beats about 100 000 times a day and pumps about 7000 L; experiments #719 and #720 measure real heart rate with the ATP SciencePod heart-rate sensor at rest and after exercise.
Key relation: Cardiac output (L/min) = stroke volume (mL) × heart rate (beats/min) ÷ 1000 | Resting: 70 mL × 70 = 4900 mL/min ≈ 4.9 L/min
Equipment used
- Mini torso (dual sex, 16 parts) (two-part heart)
- Vernier caliper
- Rubber stopper (two-hole)
- Glass delivery tube (two)
- Silicone tubing (two lengths of about 40 cm)
- Mohr clip (two)
- Graduated cylinder (100 mL)
- Digital chronometer
- Plastic bottles: one soft 0.5 L for the pump and one 1.5 L with the top cut off as the reservoir, pre-cut by the teacher (school sourced)
Questions for students
- From your stroke volume and rate, calculate what rate your pump would need to reach 4.9 L/min. Is it achievable by hand, and what does this tell you about the heart's design?
- Compare the volume delivered with both clips worked correctly and with the inlet clip left open. Relate the result to why valves matter and what backflow means.
- Both ventricles pump the same volume but the left wall is much thicker. Use your caliper measurements and the pressures in the two circuits to explain why.
What to expect
A firm squeeze of a 0.5 L bottle delivers 30 to 60 mL, close to a real stroke volume of 70 mL; at a comfortable 20 to 30 squeezes per minute the model output is 0.6 to 1.8 L/min, so you would need 70 squeezes of 70 mL per minute to match the resting heart's 4.9 L/min. In hard exercise the heart reaches about 20 L/min by raising both rate (up to 190 to 200 beats per minute in young adults) and stroke volume. On the model the left ventricle wall is clearly thicker than the right; in a real heart it is 8 to 12 mm against 3 to 5 mm. With the inlet clip left open, most of the squeezed water goes backwards and little reaches the cylinder. The heart is a double pump: the right side drives the pulmonary circuit, the left side the systemic circuit, and valves keep the flow one way. Output is stroke volume × rate, about 70 mL × 70 = 4.9 L/min at rest and up to 20 L/min in exercise. Your bottle pump followed the same rules: a bigger squeeze or a faster rhythm raised the output, and an open valve let the flow run backwards.
Run this experiment in your classroom
This experiment is part of ATP Volta — a self-contained mobile science lab that turns an ordinary classroom into a working STEM laboratory, with over 200 experiments in physics, chemistry, biology, robotics and engineering. Gali, the AI tutor built into ATP Connect, guides students through each step and answers their questions at the bench.
See the ATP Volta mobile science labTalk to our team