Skin Temperature and Thermoregulation
Log a fingertip cooling in water and rewarming, then watch a wet patch of skin cool as it dries, to see the body's temperature control in action.
What students learn
Students log fingertip temperature before, during and after one minute in cool water and read the vasoconstriction and rewarming curve. With the infrared sensor they compare a wet and a dry patch of forearm skin and measure evaporative cooling. They explain both results with negative feedback, blood-vessel control and the physics of evaporation, and they learn why humidity matters.
The science behind this experiment
- Core temperature is held near 37 °C by a negative feedback loop: temperature sensors in the skin and in the hypothalamus report to the hypothalamus, which compares the value with its set point and switches on heating or cooling responses. Skin temperature is allowed to vary widely.
- In the cold, the small arteries of the skin and the shunt vessels in the fingers constrict, so blood flow to the fingertip can fall more than tenfold. The skin cools and becomes an insulating layer; if that is not enough, the muscles shiver to generate heat.
- When the hand leaves the water, the cold signal fades, the vessels reopen and warm blood from the core rewarms the finger over several minutes. The overshoot some students see is this flush of returning blood.
- In the heat, skin vessels dilate and the 2–4 million sweat glands can secrete 1–2 L per hour. Sweat only cools when it evaporates, taking about 2.4 kJ of latent heat from the skin for every gram of water.
- Evaporation needs a gap between the water vapour pressure at the skin and in the air. Humid air closes that gap, so sweat drips instead of evaporating; moving air carries vapour away and speeds cooling, which is what fanning shows.
- The infrared sensor reads surface temperature from the heat radiation the skin emits, without touching it, so it compares two patches quickly; the contact probe is slower but follows one point continuously.
Key relation: Heat removed by evaporation (kJ) ≈ 2.4 × mass of water evaporated (g) | Heat loss from skin ∝ (skin temperature − air temperature)
Equipment used
- ATP SciencePod Science (ambient temperature, humidity)
- External temperature probe (supplied with the SciencePod Science)
- ATP SciencePod Enviro (infrared temperature) — optional, not included in LAB-002
- Beaker (500 mL)
- Thermometer (-10 to 110 °C)
- Digital chronometer
- Medical tape or sticking plaster to hold the probe (school sourced)
- Paper towels (school sourced)
- Cool water with a few ice cubes (school sourced)
Questions for students
- Read from your graph the lowest fingertip temperature and the time it took to return within 1 °C of baseline. Describe the shape of the rewarming curve and explain each part with changes in the skin's blood vessels.
- Compare the wet and dry patches at 1, 3 and 5 min, and after fanning. Use your room humidity reading to predict whether the wet patch would have cooled more or less on a humid day, and explain why.
- Core temperature stayed close to 37 °C during the whole test although the fingertip changed by more than 10 °C. Which parts of the body act as the thermostat, the heater and the radiator in this feedback loop?
What to expect
In a room at 20–24 °C a fingertip reads 28–34 °C at baseline. During the minute in 15–20 °C water the probe falls to about 17–22 °C; after removal the finger stays cold for a while, then rewarms over 3–8 min, sometimes slightly overshooting the baseline. The wet forearm patch reads 2–5 °C cooler than the dry patch while it dries, and fanning lowers it another 1–2 °C, while the dry patch stays within about 0.5 °C. Core temperature, which is not measured here, stays close to 37 °C throughout. The body defends a core temperature near 37 °C by letting the skin change: in cool water the fingertip's vessels close and it cools to near the water temperature, then warm blood reopens the skin and rewarms it over several minutes. A wet patch of skin reads 2–5 °C cooler than a dry one because evaporation takes latent heat, and humid air or still air weakens this cooling. Both curves are negative feedback made visible.
Run this experiment in your classroom
This experiment is part of ATP Volta — a self-contained mobile science lab that turns an ordinary classroom into a working STEM laboratory, with over 200 experiments in physics, chemistry, biology, robotics and engineering. Gali, the AI tutor built into ATP Connect, guides students through each step and answers their questions at the bench.
See the ATP Volta mobile science labTalk to our team