Turbidity and Clarity: What Is in the Water?
Build a soil-in-water turbidity scale in NTU, time how sand, silt and clay settle, filter the water and test what passes, then look at the sediment under the microscope.
What students learn
Students make five suspensions of fine soil in water, read their turbidity in NTU and build a calibration line. They follow one suspension as it settles for 30 min, filter another and show that turbidity drops while conductivity does not, and examine the sediment at 40× and 100×. A white-disc clarity test and a real local sample connect the beaker to rivers, water-treatment plants and the WHO guideline of less than 1 NTU.
The science behind this experiment
- Water carries matter in two ways. Suspended particles larger than about 1 µm scatter light, settle in time and are stopped by a filter; dissolved ions are thousands of times smaller, pass any paper filter, scatter no light and conduct electricity. Turbidity therefore measures the first kind and conductivity the second, and filtering changes only the first.
- A turbidity sensor shines light through the sample and measures the light scattered at 90° (nephelometry), reported in NTU against a formazin standard. It is not a mass measurement: the same gram of soil gives far higher turbidity as fine clay than as sand, because many small grains present far more surface for scattering. Your calibration line therefore applies only to your soil.
- Grains sink at a speed that grows with the square of their diameter (Stokes' law). Sand of 0.2 mm falls about 2 cm per second, silt of 0.02 mm about 1 m per hour, and clay of 0.002 mm about 1 cm per hour, so clay stays suspended for days and electrical charges on its surface keep it from clumping. In estuaries the salt in seawater cancels those charges and clay flocculates and settles, building mudflats.
- Turbid rivers are mostly eroded soil: bare fields, construction sites, deforested slopes and unpaved roads release sediment every time it rains, and rivers carry some 15 billion tonnes of it to the sea every year. In the water it blocks light to plants, clogs fish gills and carries phosphorus and microbes attached to the grains, which is why turbidity rises together with bacterial counts after storms.
- A treatment plant repeats your steps on a large scale: coagulation (aluminium or iron salts neutralise the clay charges), flocculation and sedimentation for a few hours, then sand or membrane filtration and disinfection. WHO guidance asks for turbidity below 1 NTU, and ideally much lower, before chlorination because particles shield microbes from chlorine and ultraviolet light; below 5 NTU water looks clear to the eye.
- The white-disc test is the oldest clarity measurement, the Secchi disc, used in lakes and seas since 1865; the GLOBE transparency tube does the same in a 120 cm tube. Disc depth and turbidity move in opposite directions, and light for photosynthesis reaches roughly two to three times the disc depth, so clarity decides how deep plants and algae can grow.
Key relation: Turbidity (NTU) ≈ k × suspended solids (g/L), k depends on grain size | Settling speed v ∝ d² (Stokes' law: doubling the grain diameter makes it sink 4 times faster) | Disc depth × turbidity ≈ constant for one kind of particle
Equipment used
- ATP SciencePod Science (light, external temperature, voltage, current)
- External temperature probe (supplied with the SciencePod Science)
- Projector with halogen lamp (12 V, 20 W), or a torch
- Black card to shade the light sensor (school sourced)
- Copper electrodes (2)
- Cables with crocodile clip and banana plug, red and black
- Lab power supply of the cart, set to 6 V DC
- ATP SciencePod Enviro (turbidity) — optional, not included in LAB-002
- ATP SciencePod BioChem with conductivity electrode — optional, not included in LAB-002
- Electronic balance (0.01 g)
- Graduated cylinder (100 mL)
- Glass funnel
- Filter paper
- Digital microscope (10x eyepiece; 4x, 10x, 40x objectives)
- Blank microscope slides
- Soil, table salt, clear 1.5 L and 2 L bottles, tea strainer, white card, stick, straws and cups (school sourced)
Questions for students
- Is your NTU against g/L line straight all the way? Where does it bend or stop rising, and what does that tell you about the sensor's range and about light scattered more than once in a very cloudy sample?
- What fraction of the turbidity remained after 30 min of settling? Use Stokes' law to estimate the size of the grains still suspended, and how long a 2 m deep pond would take to clear after a storm.
- Design a low-cost treatment for a village that takes water from a turbid stream, using settling, filtering and anything else you tested. State clearly what your design would not remove, and how you would check it with the sensors.
What to expect
Tap water reads 0 to 1 NTU. The series rises roughly in proportion to the soil added: about 20 to 80 NTU at 0.1 g/L, 100 to 400 at 0.5 g/L and 200 to 800 at 1 g/L, while 2 and 5 g/L usually exceed 1,000 NTU and need the 1:10 dilution; the exact slope depends on how fine the soil is. In the settling bottle sand is on the bottom within 30 s, turbidity falls to 20 to 50 % of its start by 30 min, and a clay haze of 10 to 100 NTU is still there the next day. Filtering cuts turbidity by 80 to 95 % (for example 400 to 30 NTU) but changes conductivity by less than 5 %, and the salt solution passes the filter unchanged at about 2,000 µS/cm. The disc disappears at 10 to 25 cm in the 0.1 g/L suspension and within a few centimetres at 0.5 g/L. Turbidity measures suspended particles by the light they scatter; dissolved substances are invisible to it but show up in conductivity. Sand settles in seconds, clay in days, and a paper filter removes most of the haze but none of the salt. Treatment plants settle, filter and then disinfect, aiming below 1 NTU so that chlorine can reach every microbe.
Run this experiment in your classroom
This experiment is part of ATP Volta — a self-contained mobile science lab that turns an ordinary classroom into a working STEM laboratory, with over 200 experiments in physics, chemistry, biology, robotics and engineering. Gali, the AI tutor built into ATP Connect, guides students through each step and answers their questions at the bench.