Water Quality Survey with GPS: A Brief for a Real Audience
Log pH, turbidity, conductivity, temperature and oxygen in local water samples with GPS tags, compare with WHO guidance and write a one-page water brief.
What students learn
Students collect water from five to eight local sources, from the tap to a pond or the sea, and record pH, turbidity, conductivity, temperature and dissolved oxygen with GPS tags. They compare each value with WHO drinking-water guidance and GLOBE protocols, learn what every parameter can and cannot reveal, and write a one-page water brief with a map, a table, the limits of the evidence and one recommendation.
The science behind this experiment
- pH measures acidity on a logarithmic scale. Natural waters sit mostly between 6.5 and 8.5: rain is about 5.6 because CO₂ forms carbonic acid, limestone water is 7.5 to 8.5, peat streams can be 4 to 6, and a sunlit pond can pass pH 9 in the afternoon as algae remove CO₂. Extreme pH corrodes pipes and weakens chlorine disinfection, so 6.5 to 8.5 is the usual operating range for drinking water.
- Turbidity is cloudiness measured by light scattered at 90° from suspended particles (clay, algae, debris), in nephelometric turbidity units (NTU). Particles shelter microbes from chlorine and ultraviolet light, so WHO guidance wants turbidity below 1 NTU before disinfection, and below 5 NTU where resources are limited (experiment #822).
- Conductivity counts dissolved ions. Rain carries almost none (10 to 50 µS/cm); water that has passed through soil and rock picks up calcium, magnesium, bicarbonate and chloride (100 to 800 µS/cm); road salt, sewage and irrigation push it higher; seawater reaches about 50,000 µS/cm. Above about 1,500 µS/cm water tastes salty, but high conductivity from limestone is natural and harmless (experiment #818).
- Temperature and dissolved oxygen belong together: cold water holds more oxygen (9.1 mg/L at 20 °C, 7.6 mg/L at 30 °C at saturation), fish are stressed below 5 mg/L and most die below 2 mg/L. Decomposing sewage or dead algae consume oxygen; photosynthesis adds it by day and respiration removes it by night (experiment #821).
- Causes can be natural or human. Geology, season and rain set the background; runoff from roads and fields (non-point sources), sewage outfalls and factories (point sources) change it. A single reading cannot tell them apart; comparing upstream with downstream, before and after rain, or morning with afternoon can.
- Clear is not clean. None of these sensors detects bacteria, viruses, nitrate, pesticides or heavy metals, the contaminants that make people ill. WHO guidance is that drinking water should contain no Escherichia coli in any 100 mL sample, a test only a laboratory can do. A scientific brief states plainly what the evidence shows and what it cannot show.
Key relation: Reference ranges: pH 6.5–8.5 | turbidity < 1 NTU ideal, < 5 NTU acceptable | conductivity < 1,500 µS/cm for drinking water (tap 100–800, rain 10–50, sea ≈ 50,000) | dissolved oxygen > 6 mg/L healthy, < 5 stress, < 2 hypoxia
Equipment used
- ATP SciencePod Science (pH, external temperature, GPS, light, voltage, current)
- pH electrode (supplied with the SciencePod Science)
- External temperature probe (supplied with the SciencePod Science)
- Copper electrodes (2)
- Cables with crocodile clip and banana plug, red and black
- Lab power supply of the cart, set to 6 V DC
- Projector with halogen lamp (12 V, 20 W), or a torch
- ATP SciencePod Enviro (turbidity) — optional, not included in LAB-002
- ATP SciencePod BioChem with conductivity electrode — optional, not included in LAB-002
- ATP SciencePod Enviro with dissolved oxygen electrode — optional, not included in LAB-002
- Beaker (250 mL) (one per sample)
- Gloves
- Labelled 0.5 L plastic bottles, distilled water, marker pen and camera or phone (school sourced)
- Computer or tablet with internet for the map and the brief (school sourced)
Questions for students
- Which of your sites had the highest conductivity? Decide whether the cause is more likely natural (rock, evaporation) or human (road salt, sewage, irrigation), and name one extra measurement or comparison site that would settle the question.
- Compare the pH of your rainwater with the pH of your pond at the time you sampled it. Explain both values using CO₂, and predict what the pond would read at dawn.
- Write the limits-of-evidence paragraph of your brief: what does one sample on one day miss, which contaminants are invisible to your sensors, and how would you design a follow-up survey (timing, replicates, sites) to make the conclusions stronger?
What to expect
Tap water typically reads pH 7.0 to 8.0, below 1 NTU, 100 to 800 µS/cm and, when cold, 8 to 10 mg/L of oxygen. Rainwater is slightly acidic (pH 5.5 to 6.5, from dissolved CO₂) and very low in ions (10 to 50 µS/cm). A pond reads pH 7 to 9 (higher in the afternoon as algae remove CO₂), 5 to 50 NTU, 200 to 1,000 µS/cm and 4 to 12 mg/L of oxygen depending on the hour. A road puddle is cloudy (20 to 200 NTU) and may carry salt and dust (100 to 2,000 µS/cm). Seawater reads pH 8.0 to 8.2 and about 50,000 µS/cm, 100 times a typical tap water. Most sites fall inside the ranges you can measure, yet none can be declared safe to drink from these readings alone. Five sensors and a GPS can map how local waters differ: rain is almost pure, tap water carries dissolved rock, ponds breathe with the daylight and the sea is 100 times saltier than the tap. Comparing the numbers with WHO and GLOBE ranges is the easy part; saying honestly what the evidence cannot show, above all about bacteria, is what makes a brief useful.
Run this experiment in your classroom
This experiment is part of ATP Volta — a self-contained mobile science lab that turns an ordinary classroom into a working STEM laboratory, with over 200 experiments in physics, chemistry, biology, robotics and engineering. Gali, the AI tutor built into ATP Connect, guides students through each step and answers their questions at the bench.
See the ATP Volta mobile science labTalk to our team